Abstract

To capture wind energy and to produce electrical power, many conversion systems have been proposed. This work treats also the modeling and the control of dual stator induction generator DSIG integrated in wind energy conversion system. In order to increase the flow of the power to the grid and to ensure an optimum operating point, it is very important to act on the generator side controllers and the conversion system output variables. The Proportional integral PI controllers have been widely used to control alternative machines. In this case, the inverters, which fed the DSIG, are controlled simultaneously with a displaced angle of 30°. So, the synthesis PI gains still difficult. To solve this problem, a nonlinear backstepping control is proposed. For that, the suggested study presents the comparison of the performances of the two strategies. Different simulation tests are conducted to evaluate the efficiency and the validity of the proposed control strategies. We notice that in the steady state, the two controls allow the same performance (tracking). In transient mode, the backstepping command is better in terms of response time and overshoot.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.