The two-dimensional quasi-steady conduction equation governing conduction controlled rewetting of an infinite cylinder with heat generation has been solved by Wiener–Hopf technique. The analytical solution yields the quench front temperature as a function of various model parameters such as Peclet number, Biot number and dimensionless heat generation rate. Also, the dry out heat generation rate is obtained by setting the Peclet number equal to zero, which gives the maximum permissible heat generation so as to prevent the dry out of the coolant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.