In this article, the Wiener variable step size with variance smoothening (WVSSV) technique is introduced for the utility supportive solar photovoltaic (PV) system. This system performs the function of power factor correction, compensation of nonactive component, and reduction of total harmonics distortion (THD) from the utility grid. The dc–ac converter is used in between the PV array and the common connection point and it is controlled through the WVSSV technique to produce the switching signals. The WVSSV technique presents impressive robustness and good adaptation in highly adverse nonlinear load conditions by estimating the clean and harmonic less fundamental component. The presented technique has a good convergence rate even at the starting of adapting and the step size is adjusted to eliminate the variety of noise and harmonics of nonlinear loads. The efficacy of the WVSSV control technique is presented through simulated and test results and depicts the improved steady-state as well as dynamic performances of the PV system. The THDs of grid parameters are found under the IEEE-519 standard in different working conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.