Abstract

The width of the 1332-cm−1 Raman line in diamond has been measured using 6328-Å He-Ne laser excitation and a double grating monochromator for analyzing the scattered light. The Raman and system line profiles were determined for various settings of the spectrograph entrance and intermediate slits. The Raman linewidth was determined for each setting using the method employed by Park [Phys. Lett. 22, 39 (1966)]. The average of the various determination is Δν=1.88±0.12 cm−1 FWHM.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.