Abstract

This applies to the design of a telescope system imaging spectrometer, imaging spectrometer for the characteristics of the telescope from the pre-and post-spectrometer components. Pre-telescope system parameters and imaging quality of the application of the imaging spectrometer is very important. This paper designed a spectral range of 1000nm ~ 2500nm, field of view of 28.1 ° × 0.3 °, a relatively large diameter of 1 / 4, 180mm focal length of the telescope system. Systems in a wide spectral 1000nm ~ 2500nm spectral range by the glass and two matching spectral correction of chromatic aberration, distortion control at 0.2%, to ensure good follow-up spectroscopy with the butt, this design can be used for aviation the large field, high-resolution imaging.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.