Abstract

Accurate measurement of particles of a wide size range is generally difficult in interferometric particle imaging (IPI). We propose an extended IPI technique with double or multiple imaging systems of different scattering angles and polarizations to achieve a wider measurable size range. The effects of particle size, scattering angle, polarization, and the comprehensive parameters of the imaging system on fringe patterns are thoroughly discussed. In the case of measuring water droplets, the measurable size range of the extended IPI enlarges to 10 μm-1 mm, with high-quality fringe patterns favoring the accuracy of measurement. The relative deviations of extracted diameters are no greater than 9%, demonstrating good accuracy of the particle sizing using the extended IPI technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.