Abstract

Pulsed arterial spin labeling (PASL) perfusion MRI has unique advantages for measuring cerebral blood flow (CBF) in the pediatric population. In neonates with congenital heart defects (CHDs), however, a considerable number of negative CBF values were observed in PASL perfusion images. A set of specific physiological and biophysical conditions were proposed as plausible explanations for this phenomenon, including small body size, low blood flow, prolonged tracer life time (blood T1) and the "shunt" between pulmonary and systemic circulations in CHD. An optimized PASL scheme with a restricted label volume was proposed, and experimental data demonstrated reduced spurious negative values and lower intersubject variability of perfusion measurements in neonates with CHD as compared to standard PASL sequences.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.