Abstract

Set the alarm value in the condition monitoring system of hydropower unit to monitor unit state parameters, if the difference between the two values exceeds the safety threshold, the alarm works, it is an effective method. Now the state parameters alarm values are set up mainly for the stable operation area in the unit condition monitoring system, which were not suit for low load conditions and in the process of load. To realize the full condition dynamic alarm of hydroelectric generating units, they are two ways: (1), build unit state parameter prediction model, compared predict values with the measured values. (2), set the alarm line, when the measured value exceeds the alarm line, the alarm works,. These two methods are considered the working condition head and output .This paper introduces several different alarm line settings, such as line alarm, partition line alarm, dynamic alarm curve and dynamic alarm surface.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.