Abstract

The background scattering from numerous frequently used sample adhesives has been investigated to determine the background contribution of these glues when used for inelastic neutron scattering measurements. Starting with a bare Cu sheet, different glues have been trialled, such as GE varnish, CYTOP solution, Teflon tape, Fomblin oil and two-component epoxy glue. Measurements were collected using the PELICAN cold-neutron time-of-flight spectrometer at ANSTO, which is capable of collecting data over a wide range of Q–ω space simultaneously. The results indicate that those glues containing hydrogen give much higher background signals, while those that do not contain hydrogen have a much smaller impact on the background signal. This was observed for both elastic and inelastic neutron scattering.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.