Abstract

This work summarizes the results of multiple experiments performed in the LUKOIL Neftohim Burgas Research Laboratory related to the issue of high values of hot filtration test (HFT) of the residue H-Oil hydrocracking residual oil products. After the start-up of the new residue H-Oil hydrocracker in the LUKOIL Neftohim Burgas refinery during the second half of 2015 the values of the HFT of the vacuum tower bottom product varied between 0.01 and 8.7%. It was found that the vacuum residual oil feed source has a profound effect on the processes of sedimentation in the H-Oil hydrocracker. The processing of vacuum residual oils from Arab medium, Arab heavy, and Basrah light crudes reduced the sedimentation and allowed achievement of a higher conversion. The H/C ratios of asphaltenes from all studied feeds decreased after hydrocracking. However, the decrease of the H/C ratio was the least pronounced with the Basra light asphaltenes, while the H/C ratios of asphaltenes from the vacuum residual oils originating fr...