Abstract

In the reconstruction of large complex cutaneous wounds, a myriad of mechanical devices has been designed to facilitate primary wound closure. However, there is a dearth of studies elucidating how best to achieve optimum use and efficiency of skin stretching (SS) when using the device for immediate primary closure of defects. Skin defect wounds (7 × 7 cm) were prepared on the back of three Bama miniature pigs. A total of 15 cycles of SS (cycle loading) were subsequently performed on the skin edges of the wound by EASApprox® SS system. Then, the changes in equidistant points were recorded after each cycle. After the SS test, all wounds were sutured under low tension. Skin elongation was observed at all equidistant points on the back wounds of three Bama miniature pigs. Up to an additional 1.10 to 3.75 cm of tissue was garnered. The maximum skin elongation was typically achieved within eight cycles of stretching and relaxation. Beyond this range, additional stretching cycles did not result in further skin extension. There may be a close link between mobilization range and the times of acute cyclic stretching (cycle loading) during the process of primary wound closure. However, larger studies are required to further evaluate the accuracy and effectiveness.