Abstract
Abstract An empirical correlation for the estimation of the droplet entrainment from boiling water pools is under development. The correlation is validated on the basis of experiments, taken from test facilities of different scale, which investigate the effect of several boundary conditions on the droplet entrainment. The calculated values for the droplet entrainment are in good agreement with the experimental data, indicating that relevant influences are considered in the developed correlation with an appropriate quantity. Nevertheless, the application of the correlation on scenarios with flashing pools and non-boiling pools with gas flows through the pool surface have to be investigated in the ongoing validation process. Furthermore, other experiments are needed, which consider pools containing surface-active substances to depict the influence of surface tension on the droplet entrainment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.