A fiber Bragg grating-based accelerometer with a fully metalized package is presented. Magnetron sputtering and electroplating techneques are successively adopted to metalize bare SiO2 fiber with a single Bragg grating. Laser welding techneque is adopted to fix the metal-coated fiber on the sensor component to obtain a fully metallized package without adhesives. Vibration test results demonstrate that the accelerometer has a flat frequency response over a 1-kHz bandwidth, with a resonance frequency of 3.6 kHz, wide linear measurement range of up to 8 g, and sensitivity of 1.7 pm/g.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.