Abstract
The paper presents the results of macro and microstructure testing, hardness measurements and tensile test of submerged arc welded joints of composite pipes made of two grades of steel with X6CrNi18-10 steel flat bars intended for operation in elevated temperature. The outer part of the composite pipe is made of Sandvik 3R12 steel (grade ASME 304L/SA) and has austenitic microstructure, whereas the inner pipe – of Sandvik 4L7 steel (grade ASME SA-210A1) and has ferritic pearlitic microstructure. The results of the tests were used as a base to elaborate the Welding Procedure Specification allowing to obtain high quality joints with correct structure and high mechanical properties.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.