Synopsis This report describes tests to assess the weldability, using TIG and SA welding, of duplex stainless steel (class UNS/S 31803, ASTM A 790) produced at ILVA'S Terni works. Samples taken from welded joints have been subjected to mechanical tests, metallographic analysis and corrosion testing.