Abstract

Neutron and X-ray diffraction techniques have been utilized to map residual stresses in MIG welded 7150 aluminium alloy plates with a high texture. Longitudinal (parallel to the weld seam) strain measurements were made using 40 keV X-rays whilst normal (through-thickness) and transverse strains were measured using neutrons at a pulsed spallation source. The strains have been corrected for the strong chemical composition variation across the weld. The complementarity of the methods was confirmed by comparing the strain obtained in the transverse direction. The combined results of both diffraction experiments enabled the full 3D stress tensor to be mapped across the weld in an optimized manner.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.