Abstract

Interferometric tomography can reconstruct 3D refractive-index distributions through phase-shift measurements for different beam angles. To reconstruct a complex refractive-index distribution, many projections along different directions are required. For the purpose of increasing the number of the projections, we earlier proposed a beam-angle-controllable interferometer with mechanical stages; however, the quality of reconstructed distribution by conventional algorithms was poor because the background fringes cannot be precisely controlled. To improve the quality, we propose a weighted reconstruction algorithm that can consider projection errors. We demonstrate the validity of the weighted reconstruction through simulations and a reconstruction from experimental data for three candle flames.