Abstract

Glazing materials have been found to greatly influence the performance of trombe wall systems. this is due to its role in determining the quantity of thermal energy that reaches the massive wall. in this article, a multi-criteria decision-making analysis for proper glazing selection for trombe wall system was considered, the location of interest is johannesburg metropolis. four different glazing types and four criteria were considered using the entropy method for weight determination. the four criteria considered were the solar heat gain coefficient (shgc), the u-value, visible transmittance and cost respectively. the result showed that the u-value is of utmost importance vis-a-vis other performance criteria for the glazing material. decreasing order of weights assigned was as follows; 71.2% weight factor for the u-value, 16% weight factor to cost, 10.2% weight factor to shgc and 2.6% weight factor to the visible transmittance respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.