Abstract

Lipid determination by the Smedes method was tested in an interlaboratory trial performed by nine laboratories from seven countries belonging to the West European Fish Technologists Association Analytical Methods Working Group. Five samples of fish and fishery products with different lipid contents, including two blind duplicates, were distributed among the participants. All laboratories applied a slightly modified Smedes method, which included extraction of lipids by cyclohexane and isopropanol, transfer of lipids to the cyclohexane phase by addition of water, phase separation by centrifugation, and gravimetric lipid determination. The results indicate that the RSD for reproducibility (RSD(R)) was between 4.11 and 6.31% for samples with moderate (7%) and high (14%) lipid content, depending on the sample. Larger SDs among the laboratories were obtained for a cod sample with low lipid content of 0.5%. The method is judged to be suitable as a routine method for lipid determination in fish and fishery products.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.