Abstract

Background and purposeIntensity-modulated proton therapy (IMPT) is expected to result in clinical benefits by lowering radiation dose to organs-at-risk (OARs). However, there are concerns about plan robustness due to motion. To address this uncertainty we evaluated the robustness of IMPT compared to the widely clinically used volumetric modulated arc therapy (VMAT) on weekly repeated computed tomographies (CT). Materials and methods19 patients with oesophageal cancer were evaluated. IMPT and VMAT plans were created on a planning 4-Dimensional CT (p4DCT) and evaluated on weekly repeated 4DCTs (r4DCT). In case of inadequate target coverage or unacceptable high dose to normal tissue, re-planning was performed. Dose distributions of the r4DCTs were warped to p4DCT, resulting in an estimated actual given dose (EAGD). ResultsCompared to VMAT, IMPT resulted in significantly lowered dose to heart, lungs, spleen, liver and kidneys. For IMPT, target coverage was adequate (after max 1 replanning) in 17/19 cases. In two cases target coverage remained insufficient. However, in one of these patients the summed dose was insufficient (due to tumor shrinkage) while weekly coverage was adequate. For the other patient the target coverage was also insufficient by VMAT, due to large anatomical changes during treatment. For VMAT, adequate target coverage was achieved in 18/19 cases without re-planning. However, for reasons of high OAR dose re-planning was required in two cases. ConclusionIMPT reduces the dose to OARs significantly, while achieving adequate target coverage in the majority of patients. Re-planning was necessary for both IMPT and VMAT due to anatomical changes.

Highlights

  • Background and purposeIntensity-modulated proton therapy (IMPT) is expected to result in clinical benefits by lowering radiation dose to organs-at-risk (OARs)

  • There are concerns about plan robustness due to motion. To address this uncertainty we evaluated the robustness of IMPT compared to the widely clinically used volumetric modulated arc therapy (VMAT) on weekly repeated computed tomographies (CT)

  • For IMPT, all dose constraints were met and the mean heart dose (MHD), mean lung dose (MLD) and mean spleen dose (MSD) doses decreased with respect to the VMAT plan by on average 11.8 Gy, 5.0 Gy and 5.2 Gy, respectively

Read more

Summary

Introduction

Background and purposeIntensity-modulated proton therapy (IMPT) is expected to result in clinical benefits by lowering radiation dose to organs-at-risk (OARs). There are concerns about plan robustness due to motion To address this uncertainty we evaluated the robustness of IMPT compared to the widely clinically used volumetric modulated arc therapy (VMAT) on weekly repeated computed tomographies (CT). IMPT and VMAT plans were created on a planning 4-Dimensional CT (p4DCT) and evaluated on weekly repeated 4DCTs (r4DCT). In one of these patients the summed dose was insufficient (due to tumor shrinkage) while weekly coverage was adequate. For the other patient the target coverage was insufficient by VMAT, due to large anatomical changes during treatment. For VMAT, adequate target coverage was achieved in 18/19 cases without re-planning. Conclusion: IMPT reduces the dose to OARs significantly, while achieving adequate target coverage in the majority of patients.

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.