Abstract

Purpose: To present the image‐guided process used clinically at Princess Margaret Hospital for stereotactic body radiation therapy (SBRT) of small lung lesions. Respiration correlated cone‐beam computed tomography (CBCT) was also investigated retrospectively to assess inter‐fraction and intra‐fraction target motion on the treatment unit. Method and Materials: Five patients with inoperable early stage non‐small cell lung carcinoma were treated using image‐guided SBRT. For each patient, tumor motion was assessed initially using fluoroscopy on a conventional simulator to determine the requirement for abdominal compression to limit tumor excursion. The planning computed tomography (CT) session involved both helical and four‐dimensional CT (4DCT) with compression applied as indicated by fluoroscopy. For SBRT, image guidance was achieved using a kV x‐ray tube and amorphous silicon flat‐panel detector mounted to the gantry drum of a linear accelerator (Elekta Synergy). Respiration correlated CBCT was also investigated, whereby the kV projections acquired for localization are sorted based on an internal surrogate of the respiration cycle. These sorted projections were reconstructed retrospectively to provide volumetric datasets at different phases in the respiratory cycle. Results: Respiration correlated CBCT image datasets were generated for one patient undergoing SBRT. For each treatment fraction, the lung lesion demonstrated excursions consistent with the excursion measured by 4DCT at the time of planning. The lesion was within the limits of the PTV as determined by 4DCT. Conclusion: We have established an efficient and streamlined image‐guided process that is in clinical use for SBRT of small lung lesions. A framework for on‐line respiration correlated CBCT acquisition on the treatment unit is being investigated to allow target motion to be assessed for each treatment fraction. Conflict of Interest: Princess Margaret Hospital is part of the Elekta Synergy Consortium. The research presented is supported, in part, by Elekta Inc.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.