Abstract
Flow disruption with the WEB-DL device has been used safely for the treatment of wide-neck bifurcation aneurysms, but the stability of aneurysm occlusion after this treatment is unknown. This retrospective multicenter European study analyzed short- and midterm data in patients treated with WEB-DL. Twelve European neurointerventional centers participated in the study. Clinical data and pre- and postoperative short- and midterm images were collected. An experienced interventional neuroradiologist independently analyzed the images. Aneurysm occlusion was classified into 4 grades: complete occlusion, opacification of the proximal recess of the device, neck remnant, and aneurysm remnant. Forty-five patients (34 women and 11 men) 35-74 years of age (mean, 56.3 ± 9.6 years) with 45 aneurysms treated with the WEB device were included. Aneurysm locations were the middle cerebral artery in 26 patients, the posterior circulation in 13 patients, the anterior communicating artery in 5 patients, and the internal carotid artery terminus in 1 patient. Forty-two aneurysms were unruptured. Good clinical outcome (mRS < 2) was observed in 93.3% of patients at the last follow-up. Adequate occlusion (complete occlusion, opacification of the proximal recess, or neck remnant) was observed in 30/37 patients (81.1%) in short-term follow-up (median, 6 months) and in 26/29 patients (89.7%) in midterm follow-up (median, 13 months). Worsening of the aneurysm occlusion was observed in 2/28 patients (7.1%) at midterm follow-up. The results suggest that the WEB endovascular treatment of wide-neck bifurcation aneurysms offers stable occlusion in a class of aneurysms that are historically unstable. Additionally, our data show that opacification of the WEB recess can be delineated from true neck or aneurysm remnants.
Highlights
ObjectivesMidterm Anatomic Outcome Because the goal of the study was to evaluate the quality and stability of aneurysm occlusion after WEB-DL treatment, 9 patients with additional coiling and/or stent placement or retreatment were not included in the evaluation (1 patient had both additional treatment and retreatment)
BACKGROUND AND PURPOSEFlow disruption with the WEB-DL device has been used safely for the treatment of wide-neck bifurcation aneurysms, but the stability of aneurysm occlusion after this treatment is unknown
Worsening of the aneurysm occlusion was observed in 2/28 patients (7.1%) at midterm follow-up
Summary
Midterm Anatomic Outcome Because the goal of the study was to evaluate the quality and stability of aneurysm occlusion after WEB-DL treatment, 9 patients with additional coiling and/or stent placement or retreatment were not included in the evaluation (1 patient had both additional treatment and retreatment). Short-Term Anatomic Outcome Because the goal of the study was to evaluate the quality and stability of aneurysm occlusion after WEB-DL treatment, the 6 pa-
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.