Abstract

Web openings are increasingly used in cold-formed steel beam members of buildings to facilitate ease of services. In this paper, a combination of tests and non-linear finite element analyses is used to investigate the effect of such holes on web crippling under the interior-one-flange (IOF) loading condition; the cases of both flange fastened and flange unfastened to the bearing plate are considered. The results of 61 web crippling tests are presented, with 18 tests conducted on channel sections without web openings and 43 tests conducted on channel sections with web openings. In the case of the tests with web openings, the hole was either located centred beneath the bearing plate or having a horizontal clear distance to the near edge of the bearing plate. A good agreement between the tests and finite element analyses was obtained in term of both strength and failure modes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.