Abstract

Wearable robotic exoskeletons (WREs) have been developed from orthoses as assistive devices for gait reconstruction in patients with spinal cord injury. They can solve some problems encountered with orthoses, such as difficulty in independent walking and standing up and high energy consumption during walking. The Wearable Power-Assist Locomotor (WPAL), a WRE, was developed based on a knee–ankle–foot orthosis with a single medial hip joint. The WPAL has been updated seven times during the period from the beginning of its development, in 2005, to 2020. The latest version, launched as a commercialized model in 2016, is available for medical facilities. In this retrospective study, which included updated results from previous reports, all data were extracted from development research records from July 2007 to December 2020. The records were as follows: patient characteristics [the number of participants, injury level, and the American Spinal Injury Association Impairment Scale (AIS) score], the total number of WPAL trials when aggregating the cases with all the versions or only the latest version of the WPAL, and maximum walking performance (functional ambulation category [FAC], distance, and time of continuous walking). Thirty-one patients participated in the development research. The levels of spinal cord injury were cervical (C5–C8), upper thoracic (T3–T6), lower thoracic (T7–T12), and lumbar (L1) in 10, 5, 15, and 1 of the patients, respectively. The numbers of patients with AIS scores of A, B, C, and D were 20, 7, 4, and 0, respectively. The total number of WPAL trials was 1,785, of which 1,009 were used the latest version of the WPAL. Twenty of the patients achieved an FAC score of 4 after an average of 9 (median 8, range 2–22) WPAL trials. The continuous walking distance and time improved with the WPAL were compared to the orthosis. We confirmed that the WPAL improves walking independence in people with a wide range of spinal cord injuries, such as cervical spinal cord injuries. Further refinement of the WPAL will enable its long-term use at home.

Highlights

  • Traumatic spinal cord injury (SCI) is one of the most devastating events that occur after various accidents

  • We have previously reported the effects of the Wearable Power-Assist Locomotor (WPAL) on walking ability and gait pattern in patients with various levels of SCI

  • When patients with SCI used the WPAL to walk, the orthotic parts were first attached to the thigh and lower leg cuffs; they were connected to the robotic part by themselves

Read more

Summary

Introduction

Traumatic spinal cord injury (SCI) is one of the most devastating events that occur after various accidents. The incidence rates of traumatic SCI per 1 million people per year were 14 cases in Austria (Majdan et al, 2016), 18 cases in Switzerland (Chamberlain et al, 2015), and 10 cases in Denmark (Bjornshave Noe et al, 2015), representing almost 180,000 cases annually worldwide in 2014 (Lee et al, 2014). In Japan, the estimated incidence of traumatic SCI, excluding the grade E in the Frankel scale, that is, defined as no neurological deficit/complete recovery, was 49 cases per 1 million people annually in 2010 (Miyakoshi et al, 2020). For patients with SCI, the opportunity to stand and walk occasionally is important from both physical and psychosocial perspectives

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.