Abstract

Whole-body fatigue (WBF) presents a concerning risk to construction workers, which can impact function and ultimately lead to accidents and diminished productivity. This study proposes a new WBF monitoring technique by applying the Critical Power (CP) model, a bioenergetic model, with a wrist-worn heart rate sensor. The authors modified the CP model to calculate WBF from the percentage of heart rate reserve (%HRR) and generated a personalized model via WBF perception surveys. Data were collected for two days from 33 workers at four construction sites. The results showed that the proposed technique can monitor field workers’ perceived WBF with a mean absolute error of 12.8% and Spearman correlation coefficient of 0.83. This study, therefore, demonstrates the viability of wearable WBF monitoring on construction sites to support programs aimed at improving workplace safety and productivity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.