Abstract

In gas insulated substations, the main trend is to move from <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mathrm{SF}_{6}$</tex-math></inline-formula> to more environmentally friendly alternatives. The main <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mathrm{SF}_{6}$</tex-math></inline-formula> alternatives are mixtures based on <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mathrm{CO}_{2}$</tex-math></inline-formula> , with additives of O2 and the fluorinated gases <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mathrm{C}_{4}\mathrm{F}_{7}\mathrm{N}$</tex-math></inline-formula> or <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mathrm{C}_{5}\mathrm{F}_{10}\mathrm{O}$</tex-math></inline-formula> . Mixtures with fluorinated additives of up to 10% were investigated in a test setup with a free burning arc. Gas composition was measured for each gas after mixing, and in-between some arcing sequences. Gas mixtures were investigated by three mobile gas analyzers and by three laboratories. The results showed that for clean gas mixtures, all methods showed comparable results. Determination of the heavily arced gas mixture decomposition is challenging and requires detailed laboratory analysis. A range of decomposition rates were shown for both <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mathrm{C}_{4}\mathrm{F}_{7}\mathrm{N}$</tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mathrm{C}_{5}\mathrm{F}_{10}\mathrm{O}$</tex-math></inline-formula> . In addition, the influence of the gas used for arcing on the arcing contacts made of Cu/W ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$20/80$</tex-math></inline-formula> wt%) was investigated. A higher mass loss on the anode than on the cathode was found for all contacts. There is an indication of a higher erosion rate for arcing contacts used in <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mathrm{SF}_{6}$</tex-math></inline-formula> alternatives than for those used with <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mathrm{SF}_{6}$</tex-math></inline-formula> , but further investigation is required. No major differences were found during visual inspection of the pins.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.