Abstract
Complete consolidation of ceramic particles is feasible for SLA, but print directionality is well acknowledged to be a source of structural anisotropy. By varying build direction of SLA zirconia specimens, pin-on-disk tests were carried out to evaluate any differences in wear behavior and phase composition with respect to laminar architecture. All combinations of horizontal and vertical pin-disk combinations demonstrated equivalent wear coefficients and phase transformation from monoclinic to tetragonal zirconia but do exhibit a nominal trend in run-in wear. Given that microstructural consolidation of AM ceramics is highly dependent on debind and/or sintering rather than print parameters the absence of anisotropy introduce by print parameters could benefit the application and development around AM ceramics.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.