Aiming at the problems of the low detection accuracy and difficult identification of the early weak fault signals of rolling bearings, this paper proposes a method for detecting the early weak fault signals of rolling bearings based on a double-coupled Duffing system and VMD. The influence rule of system initial value on the response characteristics of a double-coupled Duffing system is studied, and the basis for its determination is given. The frequency of the built-in power of the system is normalized, and a variance evaluation standard for the output value of the double-coupled Duffing system for weak fault signals detection is established. In order to solve the interference problem of fault monitoring signals, VMD is proposed to pre-process the fault monitoring signals. The weak fault signal detection method proposed in this paper is tested and verified by simulation signals and rolling bearing fault signals. The results show that the method proposed in this paper can detect the weak fault signal with the lowest signal-to-noise ratio reduced by 2.96 dB compared with the traditional Duffing detection system, and it can accurately detect the early weak fault signal of rolling bearings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.