Abstract

The most commonly used nondestructive inspection (NDI) technique for adhesively bonded and composite structures is the ultrasonic C-scan technique operating in a pulse-echo or through-transmission mode. They are most effective in detecting disbonds, voids, delamination and foreign inslusions, but are ineffective for the detection of weak bonds at the adhesive points. Weak bonds are mostly caused by improper surface cleaning of substrates. There is no air space at the adhesive joints where the substrate and the adhesive are in intimate contact with each other. This results in a lack of interface for ultrasound reflection required for their detection by conventional ultrasonic NDI techniques. Other ultrasonic techniques such as ultrasonic spectroscopy and ultrasonic resonance testers also suffer from the same disadvantage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.