Abstract
Purpose: To determine the design characteristics of a new tissue‐specific x‐ray computed tomography(CT)system that may potentially improved tumor specificity in CTimaging of similar Z‐material through detection of coherently scatteredphotons. Methods & Materials: Utilizing the open source Monte Carlo code system Electron Gamma Shower 5 (EGS5), we simulated coherently scatted photons for the purpose of investigating coherent scattercomputed tomography (CSCT). Unlike other simulation systems, ESG5 allows for correlation effects between molecules, which properly simulate coherent scatter. The simulated geometry mimics a “3rd generation” fan beam acquisition with a post‐scatter collimator (multi‐slit linear grid), which only permits scatter from a specific vertical segment of the phantom to be detected. The simulation consisted of a 10cm diameter cylindrical phantom of fat enclosing two 3.75cm diameter off‐center cylinders of muscle and air, centered midway between a monoenergetic (70kV) fan beam source and a bank of detection elements, which were located at a distance of 60 cm. The simulated detection elements were 1×1mm2 in area and covered a horizontal distance equivalent to a 55 degree arc centered on the source and a vertical distance of 175 mm. Results: Reconstruction of coherently scattered data was performed using filtered back projection and is comparable to previously published empirical results. Several material enhanced contrast images were generated from a single data acquisition (one tube rotation), with image intensity proportional to the amount of coherent scatter originating from a particular material at a particular location. Conclusion: These results demonstrate the utility of EGS5 to generate coherent scatter data for CSCT image investigation. Simulating scatter allows for a more feasible means to optimize acquisition parameters (photon spectrum, setup geometry, object attenuation) to create a CSCT system capable of exploiting the forward peaked nature of coherently scatteredphotons for discriminating similar Z‐material in topographic images.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.