Abstract

In this paper, the waveform characteristics and the losses of a new three phase permanent magnet generator, which has a rated power 250 W at 1000 rpm have been explored theoretically and experimentally. The proposed generator has new flux morphology with the axial and radial directions, therefore the waveform characteristics become important for this new machine. The detailed phase voltage measurements prove that the machine generates sinusoidal waveform and the total harmonic distortion (THD) is found to be sufficient for such a new prototype machine. According to the detailed experimental measurements, the machine has THD values of 0.4% and 4.7% for resistive load and no-load cases. In addition, the losses and the efficiency measurements are found to be very promising although the airgap optimization has not been completed. According to the simulation studies, the machine has the core and copper losses of 2.5 W and 23 W for loaded cases, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.