Abstract

A Rayleigh scattering-based optical fiber distributed temperature sensor (DTS) was used to perform fully-distributed temperature measurements of a vertical water column in a natural circulation heat transfer facility. Five thermocouples were collocated along the length of the DTS in the centerline of the water column. In-situ calibration was performed on the DTS recordings, which revealed the complete temperature profile of the water column during two different steady flow conditions. The uncertainty of these measurements was estimated to be ±4.2 °C. This study proves the feasibility and integrity of fiber DTS in heated liquid water applications. The results obtained with this DTS can also be used towards validation efforts of high-resolution prediction techniques such as computational fluid dynamics (CFD).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.