Abstract
AbstractConcrete structures can suffer from water permeating under stresses. This paper investigates the surface water permeability of reinforced concrete elements subjected to uniaxial tension. A testing system was developed to combine a conventional loading machine with a surface permeameter. To eliminate the effect of initial absorption of water, calibration tests were conducted on plain concrete samples with different surface saturated states. The experiment presented is designed to test the surface water permeability of a structural member under uniaxial tension. Specimens were reinforced centrally with different sizes of steel bar and fabricated with normal‐strength and high‐strength concrete. A uniaxial tensile load was applied from 0.10 to 0.80 of estimated ultimate cracking load in 0.10 increments. At the same time, water permeability was measured at each load step. Test results give the relationship between water permeability of concrete member and tensile load levels.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.