Abstract
In this paper, the close process of contra-motion check valve in countercurrent pressure difference is studied in nuclear power plant experimental circuit. The transient mathematical model is established. Through the dynamic grid technique, transient flow field in different conditions of valve closing are calculated, and dynamic properties of valve head closing process is analyzed. Through the CFD transient analysis, inherent damping principle and inhibition of water hammer principle are revealed. By writing water hammer analysis, the inhibitation ability of water hammer in typical six conditions is analyzed. At last the performance verification experiments show that contra-motion check valve can effectively inhibit water hammer in the process of parallel double pump switching transition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.