Abstract A straight, single channel membrane humidifier was constructed to measure temperature and moisture profiles along both the donor and receiver channels. A persulfonic Nafion membrane was used as the water exchange medium. We report on results obtained with single-phase vapour-to-vapour, counter flow operation. First, the heat loss to the surroundings was quantified and found to affect the overall performance significantly. Second, the results from varying flow rates indicate that lower flow rates lead to higher outlet dew point values of the receiver stream which can be related to longer residence times. It was also found that moisture transfer is more strongly influenced by the flow rate through the receiver side than the donor side. Finally, five-point dew point profiles for both donor and receiver sides are reported for various temperature conditions. No stream wise variation in moisture flux was observed, and the average flux value increased from 3.3 × 10−5 kg s−1 m−2 at 30 °C to 2.0 × 10−4 kg s−1 m−2 at 70 °C under fully humidified donor-side inlet conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.