Moisture transfers have a major effect on concrete durability. For Alkali-Silica Reaction (ASR), chemical swellings depend on water content, and drying can have important consequences. Within the framework of a large experimental study developed in partnership by the Laboratoire Central des Ponts et Chaussees (LCPC) and Electricite de France (EDF), the continuous measurements of moisture transfer in reactive concrete structures was one of the main purposes. This paper deals with the large data bank on concrete drying and water absorption, measured on six 3 m long beams with weighing and gammadensitometry devices specially designed for this study. These measurements enable some quantitative conclusions to be reached. Moreover, the data allows the validation of models of moisture transfer representing the mass variation with time in the beams. Profiles of mass variations thus obtained are the mandatory first step of calculations to estimate the mechanical behaviour of these reference or ASR damaged beams.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.