Abstract

Four water-based cold protection systems [under-benches mist (UBM), over-roadways mist (ORM), and two among-plants fog (APF1, APF2)] were evaluated for their water use and effectiveness in protecting ornamental foliage plants from chilling injury (CI) under protected shade structures at three commercial locations in Florida. UBM used a two-stage thermostat-controlled system with mist nozzles on 25-cm above-ground risers combined with an overhead retractable heat curtain. Both ORM and APF1 had seasonally applied polyethylene film cladding and manually controlled irrigation systems. The ORM system had the mist nozzles located 1.8 m high and APF1 and APF2 systems had the low-pressure fog nozzles mounted on 25-cm above-ground risers spaced among the plants. Temperature data loggers were placed outside and inside the northwest sections of the shadehouses. ORM and the two APF systems were evaluated during freeze events in 2006, 2007, and 2008 and UBM only in 2007 and 2008. UBM, ORM, and APF1 successfully kept the shadehouse temperatures above critical chilling temperatures for all of the foliage plants. APF2 protected all foliage crops except for jungle drum “palm” (Carludovica sp.) that sustained CI. At the UBM site, the air temperatures recorded inside the shadehouse were ≈17 °C warmer than outside. Both ORM and APF1 maintained adequately warm temperatures inside the shadehouses; however, the fog system maintained equal or higher temperatures than the mist system and used 86% less water. Inside temperatures were lower with APF2 than APF1 although the emitter type was the same and the water application rates were similar. These temperature differences were attributable to the greater APF2 shadehouse surface area (SA) and volume (V) compared with APF1 and indicate that the SA and V of structures being heated need to be considered when designing water-based low-pressure fog heating systems. The ORM and both fog systems conserved water compared with using the conventional sprinkler irrigation systems. These results show the potential of water-based approaches for maintaining shadehouses above chilling temperatures during freeze events.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.