Abstract
This study aimed to find an appropriate way to minimize water utility in the petrochemical and petroleum industries. For this purpose, Tehran oil refinery was chosen to analyze feasibilities of regeneration, reuse and recycling in the water network. In this research, two key contaminants including COD and hardness were analyzed. Amount of freshwater was reduced about 180 m3/h (53%) and 216.88 m3/h (63%) regarding COD and hardness respectively. In the next stage, two mentioned contaminants were analyzed simultaneously based on the mass transfer constraints. Results showed that the amount of required water was reduced from 340 m3/h to 197.12 m3/h that was about 42%. Analyzing both methods clearly demonstrated that amount of required water would be determined by mass transfer of COD. In addition, the method based on multiple contaminants gave more precise results rather than single contaminant.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.