Two waste heat recovery systems of barbershops were presented to increase its heat utilization efficiency. One was the waste heat recovery system with water-to-water heat exchanger (WHR-HE). The other is the waste heat recovery system with both water-to-water heat exchanger and heat pump (WHR-HE-HP). The two waste heat recovery systems were analyzed by both economics and thermodynamics principles. Compared to conventional heat utilization systems of barbershops, the WHR-HE decreases annual energy consumption by 54.2%, and the WHR-HE-HP decreases annual energy consumption by 87.5%. The gain investment recovery periods of WHR-HE and WHR-HE-HP are below half one year. Compared to the WHR-HE, the WHR-HE-HP is with larger energy-saving potential, lower running cost, larger first cost and larger gain investment recovery period. The critical value of energy-saving financial subsidy is 0.778 ¥/W for the WHR-HE-HP. The WHR-HE-HP is very suited to the large and medium-sized barbershops, especially in the cold climate zone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.