Abstract
A feasibility study concerning the application of the SARF technique at wafer level has been performed. The main problem of this type of measurements is the excess noise generated at the point contacts used to supply the lines under investigation with the test current. This problem has been successfully solved by setting up a probe station entirely contained in a shielded box and by supplying the samples under test by means of purposely designed low noise current sources. The background noise of the whole measurement system coincides with that of the system used until now for packaged samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.