Abstract

Results of investigations into the spatial and temporal parameters of the voluminous plasma generated by two high-current pulsed magnetron sputtering systems operating in balanced and unbalanced regimes are presented. It is demonstrated that the plasma filling the vacuum chamber comprises two components: the plasma drifting from the region of magnetron magnetic traps and the plasma generated by oscillating electrons directly in the chamber volume. For the balanced magnetron magnetic field configuration, the plasma in the centre of the vacuum chamber with volume of ~10 L has concentration of (1–2)⋅1013 cm−3 for magnetron discharge current amplitude of 350 A. The application of the unbalanced magnetic field configuration allows the plasma concentration in the central part of the vacuum chamber to be increased to ~6⋅1013 cm−3.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.