Abstract
The time-dependent lateral expansion and load relaxation of cartilage cylinders subjected to unconfined compression were simultaneously recorded. These measurements were used to (1) test the assumption of incompressibility for articular cartilage, (2) measure the Poisson's ratio of articular cartilage in compression and (3) investigate the relationship between stress relaxation and volumetric change. Mechanical tests were performed on fetal, calf, and adult humeral head articular cartilage. The instantaneous Poisson's ratio of adult cartilage was 0.49±0.08 (mean+S.D.), thus confirming the assumption of incompressibility for this tissue. The instantaneous Poisson's ratio was significantly lower for calf (0.38±0.04) and fetal cartilage (0.36±0.04). The equilibrium Poisson's ratio, i.e. true Poisson's ratio of the solid matrix, was significantly higher for the adult tissue (0.26±0.11) compared to both the fetal (0.09±0.02) and calf (0.11±0.03) cartilage. A linear relationship between time-matched load and lateral expansion after the first minute of stress relaxation was observed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.