Abstract
Personalized dosing of kinase inhibitors (KI) might be beneficial in oral anti-cancer therapy to overcome individual pharmacokinetic variability. Volumetric absorptive microsampling (VAMS) has emerged as an attractive alternative compared to conventional invasive sampling methods enabling remote and frequent specimen collection. Therefore, an LC-MS/MS VAMS method was developed and validated to monitor drug exposure of ten KI from 20 µL dried capillary blood. The assay includes the KI cabozantinib, dabrafenib, nilotinib, and osimertinib with a calibration range of 6–1500 ng/mL and afatinib, axitinib, bosutinib, lenvatinib, ruxolitinib and trametinib within a range of 2–500 ng/mL. Using acetonitrile containing isotope labelled internal standards (IS) as solid-liquid extraction solvent, analytes and IS were detected by multiple reaction monitoring (MRM) after electro-spray ionization (ESI) in positive ionization mode after chromatographic separation using a phenyl-hexyl column. The method was validated according to the FDA and EMA guidelines for bioanalytical method validation and in accordance with the guideline of the International Association for Therapeutic Drug Monitoring and Clinical Toxicology for dried blood spot-based methods. The calibration model was linear and reproducible for all KI (R2> 0.994). Furthermore, the validation demonstrated that the VAMS method is accurate, precise, and sensitive. The method fulfilled the acceptance criteria for matrix effects, recovery, carry over, selectivity as well as for the haematocrit effect and all substances proved to be stable in dried condition for at least six weeks at room temperature. In vitro experiments using spiked venous blood were conducted to establish a VAMS-to-plasma conversion factor for each analyte for comparison of VAMS and plasma concentrations. The method was successfully used in a real-life setting demonstrating its applicability in clinical routine. VAMS concentrations of afatinib, cabozantinib, dabrafenib, nilotinib, ruxolitinib and trametinib were assessed in capillary blood samples collected from either trained healthcare professionals or patients at home.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.