Abstract
We performed volume-selective 1H MR spectroscopy (1H-MRS) on 12 patients on valproate monotherapy to detect valproate in vivo in the brain. We also acquired reference valproate spectra in vitro in subphysiological 15 g/l albumin solution in saline, in which valproate showed two resonance peaks at 0.7 and 1.2 ppm and a minimum detection threshold of 240 mg/l. In vivo 1H-MRS spectra in brain showed peaks between 0.6 and 1.6 ppm. Simultaneous serum valproate concentrations did not correlate with these integrated MRS peaks. On follow-up, changes in these signals also did not correlate with increasing serum valproate levels. The inconsistency of in vivo 1H-MRS signals at varying serum levels and the high detection levels in vitro suggest that valproate signals are missed in vivo because valproate is metabolised or strongly bound, presumably to brain macromolecules.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.