Abstract

Coal chemical industry (CCI) generally utilizes reverse osmosis (RO) for water reclamation, which generates a highly concentrated stream containing refractory organic substances and high-concentration total dissolved solids (TDS). To address this issue, the present work focuses on volume reduction of RO concentrate (ROC) produced from CCI by forward osmosis (FO). We investigated the effects of membrane orientation and draw solution (DS) concentration on FO performance. Foulant removal was tested by using chemical cleaning, physical cleaning and osmotic backwash (OB). AL-FS (active layer facing feed solution) mode outcompeted AL-DS (active layer facing draw solution) mode, achieving a flux of 26.4 LMH, 92.5% water reclamation and energy consumption of 0.050 kWh·m-3 with 4 M NaCl as DS. The FO process was able to reject >98% SO4 2-, Mg2+and Ca2+, 92-98% Si and 33-55% total organic carbon (TOC). Ten-cycle (10 × 20 h) accelerated fouling test demonstrated approximately 30% flux decline in association with Si-containing foulants, which could be removed almost completely through OB with 97.1% flux recovery. This study provides a proof-of-concept demonstration of FO for volume reduction and water reclamation of ROC produced from CCI, making the treatment of ROC more efficient and more energy effective.