Abstract

To determine how much blood must be discarded before one can obtain a reliable central venous catheter blood culture, we prospectively cultured the blood (from 96 patients) that is ordinarily discarded before obtaining blood for such a culture. We then compared the prospective culture results with those of the actual blood culture. Three sequentially drawn aliquots of blood were aspirated from the central venous catheter and cultured. The culture results of the second aliquot were comparable to those of the third (the portion usually cultured) in overall sensitivity (94.4%), specificity (94.9%), and positive predictive value (80.9%). Thus, the amount of blood that must be discarded (infants: 0.3 mL; children: 1.0 mL) before one can obtain an accurate central venous catheter culture is less than was previously thought.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.