Abstract

AbstractA square‐wave voltammetric method for the determination of boric acid in water has been described based on the new understanding of the electrochemical behavior of boric acid‐Azomethine H complexation. Salicylaldehyde and H‐acid were used as the starting materials of boric acid‐Azomethine H complex and their concentrations were optimized for boric acid determination in water. A glassy carbon electrode, instead of a conventional mercury electrode, was used in the measurement. The detection limit of the proposed method was 0.10 mg B dm−3. The proposed method was successfully used for boric acid determination in the water from a seawater desalination RO plant.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.