Abstract

The electrochemical behavior of nandrolone decanoate (ND) at gold nanoparticles modified indium tin oxide (ITO) electrode was investigated. Oxidation of ND has been carried out in phosphate containing supporting electrolyte in the pH range 2.1–9.2 and a well-defined oxidation peak was noticed. The peak potential ( E p) of the oxidation peak decreases linearly with increasing pH. Linear calibration curve is obtained over the nandrolone decanoate concentration range of 50 nM to 1.5 μM at pH 7.2 with a detection limit of 1.36 × 10 −7 M. The proposed method is effectively applied to detect the concentration of ND in human blood serum and urine samples after 24 and 72 h of intramuscular injection. The method is rapid and does not require any pre-treatment.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.