Abstract

This paper presents the use of the Park's vector approach for diagnosing voltage source inverter faults, like output single-phasing and the occurrence of either a short-circuit or an open circuit of the controlled power switches. For this study, a prototype was built, having all the power terminals available for testing, including the ones for every semiconductor. For the short-circuit tests, a 17 /spl Omega/ auxiliary resistor was used, connected in parallel with the power switch to be tested, in order to limit the short-circuit current.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.