Abstract

A two-pulse method is used to determine how fast and to what degree a small spark gap can recover its voltage holdoff capability after breaking down. The first pulse is used to overvolt and break down the gap. The second pulse is used, after a time delay, to determine the voltage recovery of the gap. By varying the time delay to the second pulse, a recovery voltage versus time plot can be obtained. Time delays from 10 ?s to 100 ms have been recorded. The spark gap discharges millijoules of energy with a gap spacing of less than 1 mm. Recovery has been measured at breakdown voltages of up to 10 kV in argon, hydrogen, and a mixture of the 2 gases. The experimental setup, pulse circuits, and data collection methods are described. Percent voltage recovery versus time plots for various parameters (gas species, gap spacing, and pressure) are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.